CHIFON ELECTRIC CO.,LIMITED

BEST SERVICE, WE DRIVE!

Manufacturer from China
Active Member
4 Years
Home / Products / Motor Drive Inverter /

Asynchronous Motor 315KW Low Voltage VFD Phase Converter With Output Reactor

Contact Now
CHIFON ELECTRIC CO.,LIMITED
City:hangzhou
Province/State:zhejiang
Country/Region:china
Contact Person:Molly
Contact Now

Asynchronous Motor 315KW Low Voltage VFD Phase Converter With Output Reactor

Ask Latest Price
Brand Name :CHIFON
Model Number :FPR500A-315G/355P-T4
Certification :CE, ISO9001, SGS, EAC
Place of Origin :CHINA
MOQ :1pcs
Price :USD4041.55-USD4081.96/pc
Payment Terms :L/C, T/T, Paypal
Supply Ability :10000pcs per month
Delivery Time :sample order 2 working days, bulk order 7-10 working days
Packaging Details :Wooden case 1400*850*500mm
Adaptive Motor Model :Asynchronous Motor
Model :FPR500A-315G/355P-T4
Motor Power :315kw/420HP
Motor Phase :Three Phases
Input Voltage :380-460v
Control Mode :V/F
Output Voltage :380-460v
Frequency :50/60Hz
Color :Grey
Rated Output Current :585/650A
Outer size :1300*750*465mm
Quality Certificate :CE,ISO,SGS,EAC
Warranty :18 months
Customized :Yes
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

FPR500A High-performance Asynchronous Motor Inverter


Asynchronous Motor 315KW Low Voltage VFD Phase Converter With Output Reactor

►Power class

Single-phase 220v±15% 0.4-2.2kw
Three-phase 380V±15% 0.75-315kw

Asynchronous Motor 315KW Low Voltage VFD Phase Converter With Output Reactor

Product introduction

FPR500 series relies on TI company's DSP dual-core professional control motor chip, which supplies the international leading vector control algorithm to realize the real high-precision flux vector torque control. It has built-in pg vector control (VC), pg-free vector control (SVC), and V/F control modes, which are widely applied to high-speed control accuracy, rapid torque response, and high performance at low frequency. The integration of torque control, speed control, and position control can meet the high-performance requirements of customer applications. And, FPR 500 has the ability to exceed the anti-trip performance of similar products and adapt to the severe power grid, ambient temperature, humidity, and dust, greatly improving the reliability of products.
Asynchronous Motor 315KW Low Voltage VFD Phase Converter With Output Reactor

Asynchronous Motor 315KW Low Voltage VFD Phase Converter With Output Reactor



Certificates

Asynchronous Motor 315KW Low Voltage VFD Phase Converter With Output Reactor

Asynchronous Motor 315KW Low Voltage VFD Phase Converter With Output Reactor

Products Specifications:

Basic Function Specification
Maximum output frequency 0~500Hz
Carrier frequency 0.5kHz~16.0kHz;According to the load characteristics, carrier
frequency can be adjusted automatically
Input frequency Range :47~63Hz
Control mode V/F Open/closed loop vector control(SVC/FVC)
Speed range 1:50(Vector mode 0 ) 1Hz/150% rated torque
Overload capability G type:150% rated current for 60s;
180% rated current for 3s
P type:120% rated current for 60s;
150% rated current for 3s
Torque boost Auto Torque boost Manual Torque boost; 0.1%~30.0%.
V/F curve V/F Four modes : Line , Multi-point , Square V/F curve, V/F separation
Jog control Jog frequency range:0.00Hz to F0-10(Max frequency)
Accelerate/Decelerate curve Line or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range
of Acc/Dec Time0.0~65000.00s.
DC brake DC brake frequency: 0.00Hz to Maximum frequency
brake time: 0.0 to 36.0s
brake current value: 0.0 to 100%
Simple PLC, Multi-speed 16-speed operating through built-in PLC or control terminal
Built-in PID Close loop control system can be formed easily by using PID
Automatic voltage
regulating (AVR)
Output voltage is regulated when voltage of the power network changes
Overvoltage and over current
stall control
During operation automatically limits the inverter output current
and bus voltage, to prevent fan over current and overvoltage trip.
Rapid current limiting
function
Minimizing flow failures, protect the normal operation of the inverter
Instantaneous stop non-stop Load feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted.
Speed tracking start For high-speed rotation of the motor speed identification, impact-
free smooth start
Rapid current limit Rapid software and hardware limiting technology to avoid
frequent converter over current fault.
Virtual IO Five sets of virtual DO, five sets of virtual DI, enables easy logic control.
Timing Control Timing control: set the time range 0.0Min~6500.0Hour
Multi-motor
switch
Two independent motor parameters, enabling two motors switching control
Bus Support Two independent Modbus communication, CAN-Link
Command source Given the control panel, control terminal, serial communication port given. It
can be switched by a variety of ways.
Torque boost Auto Torque boost Manual Torque boost ; 0.1%~30.0%.
Frequency source Nine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways.
Auxiliary
frequency source
Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary
frequency tuning, frequency synthesis.
Input terminal Six digital input terminals, one only supports 50khz high pulse input
Two analog input terminals, one support 0V~10V voltage input
One support 0 ~ 10V voltage input or 0 ~ 20mA current input
Output
terminal
One high-speed pulse output terminal (optional open collector type), support of
square wave 0 ~ 50kHz signal output
One digital output terminal
One relay output terminals
Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V
voltage output
Display and operation
LED display Display parameters and status information
The key lock and function selection Achieve some or all of the keys locked, scope definition section keys
to prevent misuse.
Protection function Input/output phase failure protection ,Overcurrent protection ;Over
voltage protection; Undervoltage protection; Overheat protection ;
Overload protection
Options Brake assembly, PG card
Environment
Application environment In-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt .
Altitude Lower than 1000m
Vibration Less than 5.9m/s(0.6g)



FAQ:

What is a variable frequency drive?

A VFD is used to control the speed of an AC induction motor. it can do this by varying the motors supplied voltage and changing the frequency of the power. Three major designs are used in VFD they are pulse width modulation, current source inverter, and voltage source inverter

It has become the most common drive controller it is because a VFD works very well with motor ranging, it is highly reliable, affordable, and it only reflects the least amount of harmonics back to the power source.

Fault conditions in VFD (motor fault analysis)

  • Rolling element bearing faults
  • Sleeve bearing faults
  • Imbalance
  • Misalignment
  • Soft foot conditions
  • Mechanical resonances
  • Rotor winding failure
  • Stator winding failure
  • VFD carrier frequencies
  • Air gap issues

Troubleshooting VFDs

If you have an unidentified wide frequency band vibration fault it is possible that it is a VFD problem. It can be corrected by additional tuning of torque profiles, carrier frequencies, or smoothing parameters may correct the issue